Audi Audi S4 2003-2008 HVAC Specifications
Detailed technical specifications and operational insights for the HVAC system in the 2003-2008 Audi S4. Learn about system components, refrigerant requirements, and troubleshooting tips for optimal performance.
Overview Specifications
Comprehensive description of the HVAC specifications for the 2003-2008 Audi S4, including key features, measurements, and technical details. This section covers the heating, ventilation, and air conditioning system, focusing on its components, performance, and maintenance requirements.
How to Use
Use the search function to locate specific HVAC specifications by entering keywords such as 'blower motor', 'refrigerant capacity', or 'temperature control'. Use exact terms for precise results.
Navigate through the HVAC documentation sections using the table of contents. Each major section is divided into subsections for detailed technical information.
Key Specifications
Cooling Capacity
12,000 BTU/h (3.5 kW)
Refrigerant Capacity
700 g (24.7 oz)
Airflow Rate
450 m³/h (265 CFM)
Temperature Range
16°C to 32°C (60°F to 90°F)
Blower Motor Resistance
2.5-3.5 ohms
Available Specifications
HVAC System Overview
This section provides an overview of the HVAC system, including its components, functionality, and integration with the vehicle's electrical and mechanical systems.
HVAC System Overview
This section provides an overview of the HVAC system, including its components, functionality, and integration with the vehicle's electrical and mechanical systems.
System Components
- Dual-zone automatic climate control system
- Electrically driven compressor for refrigerant circulation
- High-capacity blower motor with variable speed control
- Integrated cabin air filter for improved air quality
- Evaporator and condenser units for heat exchange
System Performance
- Cooling capacity: 12,000 BTU/h (3.5 kW)
- Heating capacity: 5,000 BTU/h (1.5 kW)
- Refrigerant type: R134a, capacity: 700 g (24.7 oz)
- Airflow rate: Up to 450 m³/h (265 CFM)
- Temperature control range: 16°C to 32°C (60°F to 90°F)
Note: Performance metrics are based on standard operating conditions at 25°C (77°F) ambient temperature.
HVAC Controls and Sensors
This section details the control mechanisms and sensors used in the HVAC system, including their functions and technical specifications.
HVAC Controls and Sensors
This section details the control mechanisms and sensors used in the HVAC system, including their functions and technical specifications.
Control Panel
- Dual-zone digital temperature control with LCD display
- Adjustable fan speed with 7-speed settings
- Automatic recirculation mode for air quality management
- Defrost and defog settings with automatic activation
- Integration with Audi MMI (Multi Media Interface)
Sensors
- Interior temperature sensor with ±0.5°C accuracy
- Exterior temperature sensor with weather compensation
- Sunlight sensor for solar load adjustment
- Humidity sensor for defogging optimization
- Pressure sensor for refrigerant system monitoring
Note: Sensor data is processed by the HVAC control module for precise climate management.
HVAC Maintenance and Diagnostics
This section covers maintenance procedures, diagnostic tools, and troubleshooting tips for the HVAC system.
HVAC Maintenance and Diagnostics
This section covers maintenance procedures, diagnostic tools, and troubleshooting tips for the HVAC system.
Maintenance Procedures
- Cabin air filter replacement interval: 15,000 miles or 12 months
- Refrigerant system inspection every 30,000 miles
- Blower motor lubrication: Not required (sealed unit)
- Evaporator cleaning: Recommended every 50,000 miles
- System pressure check during routine service
Diagnostics
- OBD-II compatible for fault code retrieval
- HVAC-specific diagnostic codes available via VCDS (VAG-COM)
- Pressure and temperature readings accessible through diagnostic tools
- Blower motor resistance check: 2.5-3.5 ohms
- Compressor clutch engagement test: 12V DC input
Note: Use Audi-approved diagnostic tools for accurate troubleshooting.
Search Specifications
Search by specification name, value, or description
Type to search through torque specifications. Results will appear below as you type.
Component Specifications
General Specifications
- System Type
- Automatic Climate Control
- Refrigerant Type
- R134a
- Refrigerant Capacity
- 525 ± 25 grams
- Compressor Type
- Variable Displacement
- Compressor Oil Type
- PAG 46
- Compressor Oil Capacity
- 150 ± 10 ml
Blower Motor
- Power Rating
- 200W
- Voltage
- 12V DC
- Speed Settings
-
- Low
- Medium
- High
- Auto
- Part Number
- 8E0820041C
Heating System
- Heater Core Material
- Aluminum
- Heater Core Dimensions
- 300mm x 150mm x 40mm
- Max Heater Output
- 6.5 kW
- Coolant Flow Rate
- 12 L/min
- Part Number
- 8E0820401A
Air Conditioning
- Evaporator Material
- Aluminum
- Evaporator Dimensions
- 250mm x 200mm x 50mm
- Cooling Capacity
- 4.2 kW
- Expansion Valve Type
- Thermostatic
- Part Number
- 8E0820043B
Air Distribution
- Vent Types
-
- Dashboard Vents
- Floor Vents
- Defrost Vents
- Vent Material
- ABS Plastic
- Airflow Capacity
- 450 m³/h
- Recirculation Mode
- Automatic/Manual
- Part Number
- 8E0820105D
Sensors
- interior Temperature Sensor
- Type: NTC ThermistorRange: -40°C to 85°CAccuracy: ±1°CPart Number: 8E0820543A
- Exterior Temperature Sensor
- Type: NTC ThermistorRange: -40°C to 85°CAccuracy: ±1°CPart Number: 8E0820543B
- Sunlight Sensor
- Type: PhotodiodeRange: 0 to 1000 W/m²Accuracy: ±5%Part Number: 8E0820543C
Control Unit
- Type
- Digital Microprocessor
- Operating Voltage
- 12V DC
- Temperature Setting Range
- 16°C to 30°C
- Part Number
- 8E0820047E
Filters
- Cabin Air Filter
- Type: Activated CarbonDimensions: 200mm x 150mm x 25mmReplacement interval: 15,000 miles or 12 monthsPart Number: 8E0819439A
- Pollen Filter
- Type: PaperDimensions: 200mm x 150mm x 25mmReplacement interval: 15,000 miles or 12 monthsPart Number: 8E0819439B
Operational Parameters
- Temperature Control Accuracy
- ±0.5°C
- Humidity Control Range
- 30% to 70% RH
- Max System Pressure
- 30 bar
- Min System Pressure
- 2 bar
Diagnostics
- Fault Codes
-
- P0532
- P0533
- P0534
- P0535
- Diagnostic Tool
- VAG-COM
- Self Diagnosis Mode
- Yes
- Error Memory Capacity
- 20 faults
Service Information Service
Detailed service requirements and schedules for the HVAC system
- Inspect and replace cabin air filter
- Check refrigerant level
- Inspect blower motor operation
- Check all HVAC sensors
Use only Audi-approved refrigerant and lubricants
- Inspect and replace pollen filter
- Check compressor operation
- Inspect heater core for leaks
- Check evaporator for blockages
Perform a full system pressure test
- Replace refrigerant
- Inspect and clean all vents
- Check control unit functionality
- Perform a full system diagnostic
Ensure all connections are secure and free of corrosion
Frequently Asked Questions
Find answers to common questions about torque specifications
Q1 What is the refrigerant type and capacity for the 2003-2008 Audi S4 HVAC system?
What is the refrigerant type and capacity for the 2003-2008 Audi S4 HVAC system?
The 2003-2008 Audi S4 HVAC system uses R134a refrigerant. The total system capacity is approximately 750 grams (26.5 ounces). Always refer to the service manual for precise charging instructions.
Q2 How do I reset the HVAC system after replacing the cabin air filter?
How do I reset the HVAC system after replacing the cabin air filter?
To reset the HVAC system, turn the ignition to the 'ON' position, press and hold the 'ECON' and 'AUTO' buttons simultaneously for 5 seconds. The system will reset, and the display will confirm the reset.
Q3 What is the recommended interval for servicing the HVAC system?
What is the recommended interval for servicing the HVAC system?
Audi recommends inspecting the HVAC system every 20,000 miles or 2 years, whichever comes first. This includes checking refrigerant levels, cabin air filter replacement, and inspecting for leaks or blockages.
Q4 How do I diagnose a malfunctioning HVAC blower motor?
How do I diagnose a malfunctioning HVAC blower motor?
A malfunctioning blower motor may exhibit symptoms such as no airflow or unusual noises. Check the blower motor resistor, fuses, and wiring harness for faults. Use a multimeter to test the motor's voltage and resistance. Replace the motor if it fails to operate within specifications.
Q5 What is the procedure for evacuating and recharging the HVAC system?
What is the procedure for evacuating and recharging the HVAC system?
To evacuate and recharge the HVAC system, connect a refrigerant recovery machine to the low and high-pressure service ports. Evacuate the system to a vacuum of at least 29 inHg for 30 minutes. Recharge with the specified amount of R134a refrigerant, ensuring proper pressure levels are achieved.
Factory Service Resources
Access official service manuals, technical documents, and repair guides. These resources provide detailed procedures, specifications, and diagrams directly from the manufacturer.
Audi S4 HVAC System Service Manual
Coming SoonOfficial service manual for the 2003-2008 Audi S4 HVAC system, including detailed repair procedures and specifications.
HVAC Troubleshooting Guide
Coming SoonStep-by-step guide to diagnosing and resolving common HVAC issues in the 2003-2008 Audi S4.
Refrigerant Handling and Safety
Coming SoonComprehensive guide on handling R134a refrigerant safely, including proper disposal and environmental regulations.
Cabin Air Filter Replacement Tutorial
Coming SoonDetailed tutorial on replacing the cabin air filter in the 2003-2008 Audi S4, including resetting the HVAC system.
About the Author
Expert automotive knowledge and experience
Diagnostic
Specialized in advanced diagnostic techniques using modern scan tools and oscilloscopes.
Repair
Expert in both traditional mechanical repairs and modern vehicle systems.
Additional Expertise
Documentation
Created over 500 detailed repair guides and technical documents.
Training
Conducted technical training sessions and contributed to repair databases.
Certifications & Research
Certifications
- ASE Master Technician Certification
- Advanced Diagnostic Specialist
- Hybrid/Electric Vehicle Systems
- Performance Tuning Expert
Research & Community
Actively researches emerging technologies and contributes to automotive forums.
Legal Disclaimer
Important information about using this content
Always refer to your vehicle's service manual and take appropriate safety precautions when performing any maintenance or repairs.
General Information
Warranty & Liability
The content on this website is provided "as is" without any representations or warranties, express or implied. We make no representations or warranties regarding the accuracy, completeness, or availability of the information.
We shall not be liable for any direct, indirect, special, or consequential damages arising from the use of information on this website.
Technical Information
- All specifications, including torque values, fluid capacities, and maintenance procedures, should be verified against your vehicle's factory service manual.
- Vehicle specifications and procedures may vary by model year, trim level, and region.
- Always follow the manufacturer's recommended procedures and safety precautions.
- Working on vehicles can be dangerous. Always take proper safety precautions and use appropriate safety equipment.
- If you're unsure about any procedure, consult a qualified professional mechanic.