Audi Audi RS4 2018-present HVAC Specifications
Detailed technical specifications and performance metrics for the HVAC system in the 2018-Present Audi RS4. Includes component details, refrigerant types, control mechanisms, and diagnostic procedures.
Overview Specifications
Comprehensive description of the HVAC specifications for the 2018-Present Audi RS4, including key features, measurements, and technical details. This section provides detailed insights into the heating, ventilation, and air conditioning system, ensuring optimal performance and comfort.
How to Use
Use the search function to locate specific HVAC specifications by entering keywords such as 'blower motor', 'refrigerant capacity', or 'temperature control'. Use exact terms for precise results.
Navigate through the HVAC documentation sections using the table of contents. Each major section is divided into subsections for easy access to specific technical details.
Key Specifications
Refrigerant Type
R1234yf
Refrigerant Capacity
525 ± 25 g
Heater Core Output
6.5 kW at 90°C
Cabin Air Filter Efficiency
99.7%
Temperature Control Range
16°C to 30°C (60.8°F to 86°F)
Available Specifications
Climate Control System
Details about the advanced climate control system in the Audi RS4, including dual-zone temperature control, air distribution, and system components.
Climate Control System
Details about the advanced climate control system in the Audi RS4, including dual-zone temperature control, air distribution, and system components.
Dual-Zone Temperature Control
- Independent temperature control for driver and front passenger
- Temperature range: 16°C to 30°C (60.8°F to 86°F)
- Precision control with 0.5°C increments
- Automatic climate control with humidity sensor
Air Distribution System
- Four-zone air distribution: face, footwell, windshield, and side vents
- Adjustable airflow intensity with 7-speed blower motor
- Automatic air recirculation mode with pollutant sensor
- Defrost function for windshield and side windows
Note: The air distribution system is optimized for rapid cabin temperature adjustment.
Heating and Cooling Components
Technical specifications of the heating and cooling components, including the heater core, evaporator, and refrigerant system.
Heating and Cooling Components
Technical specifications of the heating and cooling components, including the heater core, evaporator, and refrigerant system.
Heater Core Specifications
- High-efficiency aluminum heater core
- Heat output: 6.5 kW at 90°C coolant temperature
- Compact design for space optimization
- Integrated temperature control valve
Refrigerant System
- Refrigerant type: R1234yf
- Refrigerant capacity: 525 ± 25 g
- Evaporator temperature range: 2°C to 10°C (35.6°F to 50°F)
- High-pressure cut-off: 32 bar (464 psi)
Note: The refrigerant system is designed for eco-friendly operation and compliance with global standards.
HVAC Electrical Components
Information about the electrical components of the HVAC system, including sensors, actuators, and control modules.
HVAC Electrical Components
Information about the electrical components of the HVAC system, including sensors, actuators, and control modules.
Temperature Sensors
- Interior temperature sensor accuracy: ±0.5°C
- Exterior temperature sensor range: -40°C to 85°C (-40°F to 185°F)
- Solar radiation sensor for automatic climate adjustment
- Humidity sensor for defogging control
Actuators and Control Modules
- Stepper motor actuators for air flap control
- PWM-controlled blower motor with 7-speed settings
- Integrated HVAC control module with CAN bus communication
- Diagnostic interface for system troubleshooting
Note: The HVAC control module supports over-the-air updates for enhanced functionality.
Maintenance and Service
Guidelines for maintaining and servicing the HVAC system, including filter replacement, refrigerant recharge, and system diagnostics.
Maintenance and Service
Guidelines for maintaining and servicing the HVAC system, including filter replacement, refrigerant recharge, and system diagnostics.
Cabin Air Filter
- Dual-layer activated carbon filter
- Replacement interval: 15,000 km or 12 months
- Filter dimensions: 250 mm x 200 mm x 25 mm
- Particle filtration efficiency: 99.7%
Refrigerant Recharge
- Recommended refrigerant pressure: 8-10 bar (116-145 psi) at 25°C
- Recharge interval: As per system diagnostics
- Use only R1234yf refrigerant
- Vacuum and recharge procedure requires specialized equipment
Note: Improper refrigerant handling can damage the system and void the warranty.
Search Specifications
Search by specification name, value, or description
Type to search through torque specifications. Results will appear below as you type.
Component Specifications
General Specifications
- System Type
- Automatic Dual-Zone Climate Control
- Refrigerant Type
- R1234yf
- Refrigerant Capacity
- 500 ± 20 g
- Compressor Type
- Variable Displacement
- Blower Motor Power
- 200 W
- Airflow Capacity
- 1200 m³/h
Temperature Control
- Temperature Range
- 16°C to 30°C
- Temperature Resolution
- 0.5°C
- Sensor Accuracy
- ±0.5°C
- Auto Mode Response Time
- 5-10 minutes
Air Distribution
- Vent Modes
-
- Face
- Foot
- Defrost
- Combination
- Airflow Direction Adjustment
- Manual and Automatic
- Recirculation Mode
- Automatic and Manual
- Air Quality Sensor
- Integrated PM2.5 and VOC Sensor
Heating System
- Heater Core Type
- Aluminum
- Heater Core Capacity
- 5.5 kW
- Coolant Flow Rate
- 10 L/min
- Auxiliary Heater
- Electric PTC Heater
- Auxiliary Heater Power
- 1.5 kW
Cooling System
- Evaporator Type
- Plate and Fin
- Evaporator Capacity
- 4.2 kW
- Condenser Type
- Parallel Flow
- Condenser Capacity
- 6.0 kW
- Expansion Valve Type
- Thermostatic
Filters
- Cabin Air Filter Type
- Combination Particle and Activated Carbon
- Cabin Air Filter Part Number
- 4M0819439
- Filter Replacement interval
- 15,000 miles or 12 months
- Pollen Filter Efficiency
- 99% at 0.3 microns
Electrical Specifications
- System Voltage
- 12 V DC
- Compressor Clutch Power
- 60 W
- Blower Motor Current
- 16 A
- Control Module Part Number
- 8W0907044
- Fuse Rating
- 40 A
Diagnostic Specifications
- Diagnostic interface
- ODB-II
- Fault Codes
-
- B10A0
- B10A1
- B10A2
- Self Diagnosis Mode
- Integrated in MMI System
- Sensor Failure Detection
- Automatic
Maintenance Specifications
- Refrigerant Recharge interval
- Every 2 years or 24,000 miles
- System Pressure Check
- Annual
- Lubricant Type
- PAG Oil
- Lubricant Quantity
- 150 ± 10 ml
- Leak Test interval
- Every 12 months
Safety Specifications
- High Pressure Cutoff
- 32 bar
- Low Pressure Cutoff
- 1.5 bar
- Overheat Protection
- Thermal Fuse at 120°C
- Short Circuit Protection
- Integrated in Control Module
Service Information Service
Detailed service requirements and schedules for the HVAC system
- Replace cabin air filter
- Check refrigerant level
- Inspect compressor and belts
Ensure all connections are secure and free of leaks
- Recharge refrigerant
- Inspect and clean evaporator and condenser
- Check electrical connections
Use only Audi-approved refrigerant and lubricants
- Replace blower motor if necessary
- Inspect and replace expansion valve if needed
- Perform full system diagnostic
Ensure all sensors are calibrated correctly
Frequently Asked Questions
Find answers to common questions about torque specifications
Q1 What is the refrigerant type and capacity for the 2018-Present Audi RS4 HVAC system?
What is the refrigerant type and capacity for the 2018-Present Audi RS4 HVAC system?
The HVAC system in the 2018-Present Audi RS4 uses R-1234yf refrigerant, with a total system capacity of approximately 525 grams (18.5 ounces). This refrigerant is environmentally friendly and complies with EU regulations.
Q2 How does the dual-zone automatic climate control system work in the Audi RS4?
How does the dual-zone automatic climate control system work in the Audi RS4?
The dual-zone automatic climate control system allows the driver and front passenger to set individual temperature preferences. The system uses multiple sensors, including interior temperature sensors, sunlight sensors, and humidity sensors, to maintain the desired climate. The temperature range is adjustable from 16°C (60.8°F) to 28°C (82.4°F) in 0.5°C increments.
Q3 What is the airflow rate of the HVAC system in the Audi RS4?
What is the airflow rate of the HVAC system in the Audi RS4?
The HVAC system in the Audi RS4 can deliver a maximum airflow rate of up to 12.5 cubic meters per minute (442 cubic feet per minute) when the system is set to the highest fan speed. This ensures rapid cooling or heating of the cabin.
Q4 How do I reset the HVAC system in my Audi RS4?
How do I reset the HVAC system in my Audi RS4?
To reset the HVAC system, turn the ignition on but do not start the engine. Set the temperature to maximum heat and the fan speed to the lowest setting. Press and hold the recirculation button for 5 seconds until the system resets. This procedure clears any stored error codes and recalibrates the system.
Q5 What are the maintenance intervals for the HVAC system in the Audi RS4?
What are the maintenance intervals for the HVAC system in the Audi RS4?
Audi recommends inspecting the HVAC system every 15,000 miles or 12 months, whichever comes first. This includes checking the refrigerant level, cleaning or replacing the cabin air filter, and inspecting the system for leaks or damage. Regular maintenance ensures optimal performance and longevity.
Factory Service Resources
Access official service manuals, technical documents, and repair guides. These resources provide detailed procedures, specifications, and diagrams directly from the manufacturer.
Audi RS4 HVAC System Service Manual
Coming SoonOfficial service manual detailing the HVAC system components, maintenance procedures, and troubleshooting steps for the 2018-Present Audi RS4.
Refrigerant Handling and Safety Guidelines
Coming SoonComprehensive guide on handling R-1234yf refrigerant, including safety precautions, proper disposal methods, and equipment requirements.
Cabin Air Filter Replacement Guide
Coming SoonStep-by-step instructions for replacing the cabin air filter in the 2018-Present Audi RS4, including tools required and safety tips.
Audi HVAC System Troubleshooting
Coming SoonDetailed troubleshooting guide for common HVAC system issues in the Audi RS4, including error codes and diagnostic procedures.
About the Author
Expert automotive knowledge and experience
Diagnostic
Specialized in advanced diagnostic techniques using modern scan tools and oscilloscopes.
Repair
Expert in both traditional mechanical repairs and modern vehicle systems.
Additional Expertise
Documentation
Created over 500 detailed repair guides and technical documents.
Training
Conducted technical training sessions and contributed to repair databases.
Certifications & Research
Certifications
- ASE Master Technician Certification
- Advanced Diagnostic Specialist
- Hybrid/Electric Vehicle Systems
- Performance Tuning Expert
Research & Community
Actively researches emerging technologies and contributes to automotive forums.
Legal Disclaimer
Important information about using this content
Always refer to your vehicle's service manual and take appropriate safety precautions when performing any maintenance or repairs.
General Information
Warranty & Liability
The content on this website is provided "as is" without any representations or warranties, express or implied. We make no representations or warranties regarding the accuracy, completeness, or availability of the information.
We shall not be liable for any direct, indirect, special, or consequential damages arising from the use of information on this website.
Technical Information
- All specifications, including torque values, fluid capacities, and maintenance procedures, should be verified against your vehicle's factory service manual.
- Vehicle specifications and procedures may vary by model year, trim level, and region.
- Always follow the manufacturer's recommended procedures and safety precautions.
- Working on vehicles can be dangerous. Always take proper safety precautions and use appropriate safety equipment.
- If you're unsure about any procedure, consult a qualified professional mechanic.