Audi Audi RS3 2017-present HVAC Specifications
Detailed technical specifications for the HVAC system in the 2017-Present Audi RS3, including component details, performance metrics, and diagnostic procedures.
Overview Specifications
Comprehensive description of the HVAC specifications for the 2017-Present Audi RS3, including key features, measurements, and technical details. This section provides detailed insights into the heating, ventilation, and air conditioning system, ensuring optimal performance and comfort.
How to Use
Use the search function to locate specific HVAC specifications by entering keywords such as 'blower motor', 'refrigerant capacity', or 'temperature control'. Use exact terms for precise results.
Navigate through the HVAC documentation sections using the table of contents. Each major section is divided into subsections for detailed technical information.
Key Specifications
Temperature Control Range
16°C to 30°C (60.8°F to 86°F)
Refrigerant Capacity
550 g (1.21 lbs)
Heating Capacity
6.5 kW (22,178 BTU/h)
Airflow Capacity
12 m³/min (423.8 ft³/min)
Cabin Air Filter Efficiency
99.7% for particles > 0.3 µm
Available Specifications
Climate Control System
This section covers the advanced climate control system of the Audi RS3, including its dual-zone automatic temperature control, air distribution, and filtration features.
Climate Control System
This section covers the advanced climate control system of the Audi RS3, including its dual-zone automatic temperature control, air distribution, and filtration features.
Dual-Zone Automatic Climate Control
- Independent temperature control for driver and front passenger
- Temperature range: 16°C to 30°C (60.8°F to 86°F)
- Automatic air recirculation based on air quality sensors
- Includes humidity and solar sensors for optimal comfort
Air Distribution System
- Four adjustable air vents for front passengers
- Rear air vents with adjustable flow control
- Airflow capacity: Up to 12 m³/min (423.8 ft³/min)
- Includes defrost and footwell air distribution modes
Note: Airflow capacity may vary based on fan speed settings.
Heating and Cooling Components
This section details the heating and cooling components, including the heater core, evaporator, and refrigerant system.
Heating and Cooling Components
This section details the heating and cooling components, including the heater core, evaporator, and refrigerant system.
Heater Core Specifications
- Material: Aluminum with high thermal conductivity
- Heating capacity: 6.5 kW (22,178 BTU/h)
- Coolant flow rate: 12 L/min (3.17 gal/min)
- Operating temperature range: 80°C to 110°C (176°F to 230°F)
Refrigerant System
- Refrigerant type: R-1234yf
- Refrigerant capacity: 550 g (1.21 lbs)
- Compressor type: Variable displacement
- Evaporator temperature range: 2°C to 10°C (35.6°F to 50°F)
Note: Refrigerant capacity must be verified during servicing.
Air Filtration and Quality
This section focuses on the air filtration system, including the cabin air filter and air quality sensors.
Air Filtration and Quality
This section focuses on the air filtration system, including the cabin air filter and air quality sensors.
Cabin Air Filter
- Filter type: Activated carbon with multi-layer filtration
- Particle filtration efficiency: 99.7% for particles > 0.3 µm
- Replacement interval: Every 15,000 km (9,320 miles) or 12 months
- Dimensions: 250 mm x 200 mm x 25 mm (9.84 in x 7.87 in x 0.98 in)
Air Quality Sensors
- Detects CO2, NOx, and particulate matter levels
- Automatic air recirculation activation threshold: 1,000 ppm CO2
- Sensor response time: < 5 seconds
- Operating temperature range: -20°C to 70°C (-4°F to 158°F)
Note: Sensor calibration is required during maintenance.
Search Specifications
Search by specification name, value, or description
Type to search through torque specifications. Results will appear below as you type.
Component Specifications
General Specifications
- System Type
- Automatic Dual-Zone Climate Control
- Refrigerant Type
- R1234yf
- Refrigerant Capacity
- 525 ± 25 g
- Compressor Type
- Variable Displacement
- Blower Motor Type
- Electronically Controlled
- Air Filter Type
- Cabin Air Filter with Activated Carbon
Temperature Control
- Temperature Range
- 16°C to 30°C
- Temperature Resolution
- 0.5°C
- Dual Zone Difference Limit
- 4°C
- Auto Mode Response Time
- 5-10 seconds
Airflow Specifications
- Max Airflow Rate
- 12 m³/min
- Fan Speed Levels
- 7
- Air Distribution Modes
-
- Face
- Foot
- Defrost
- Combination
- Recirculation Mode
- Automatic and Manual
Heating System
- Heater Core Type
- Aluminum
- Heater Core Flow Rate
- 5.5 L/min
- Max Heating Output
- 6.5 kW
- Coolant Flow Control
- Electronically Regulated Valve
Cooling System
- Evaporator Type
- Plate and Fin
- Evaporator Capacity
- 3.5 kW
- Condenser Type
- Parallel Flow
- Condenser Capacity
- 4.2 kW
- Compressor Power Consumption
- 400 W
Air Quality System
- Cabin Air Filter Part Number
- 8V0820443
- Filter Replacement interval
- 15,000 miles or 12 months
- Ionizer Present
- true
- Air Quality Sensor Type
- Dual-Sensor (Particulate and Gas)
Electrical Specifications
- System Voltage
- 12 V DC
- Blower Motor Power
- 200 W
- Compressor Clutch Voltage
- 12 V DC
- Control Module Part Number
- 8V0907044B
Operational Limits
- Max Ambient Temperature
- 50°C
- Min Ambient Temperature
- -30°C
- Max System Pressure
- 30 bar
- Min System Pressure
- 2 bar
Diagnostic Specifications
- Diagnostic interface
- OBD-II
- Fault Code Storage
- Non-Volatile Memory
- Self Diagnosis Capability
- true
- Common Fault Codes
-
- B10A1
- B10A2
- B10A3
Maintenance Specifications
- Refrigerant Recharge interval
- Every 2 years or 24,000 miles
- System Leak Check interval
- Every 12 months
- Compressor Oil Type
- PAG 46
- Compressor Oil Capacity
- 120 ± 10 ml
Service Information Service
Detailed service requirements and schedules for the HVAC system
- Inspect and replace cabin air filter
- Check refrigerant level and pressure
- Inspect compressor belt for wear
Replace cabin air filter more frequently in dusty environments
- Perform system leak check
- Recharge refrigerant if necessary
- Inspect and clean evaporator and condenser coils
Use only R1234yf refrigerant for recharging
- Inspect and replace compressor oil
- Check and calibrate temperature sensors
- Inspect blower motor and electrical connections
Ensure all electrical connections are secure and corrosion-free
Frequently Asked Questions
Find answers to common questions about torque specifications
Q1 What is the refrigerant type and capacity for the 2017-Present Audi RS3 HVAC system?
What is the refrigerant type and capacity for the 2017-Present Audi RS3 HVAC system?
The 2017-Present Audi RS3 HVAC system uses R-1234yf refrigerant, with a total system capacity of approximately 525 grams (± 25 grams). This refrigerant is environmentally friendly and complies with EU regulations.
Q2 What is the airflow rate of the HVAC system in the Audi RS3?
What is the airflow rate of the HVAC system in the Audi RS3?
The HVAC system in the Audi RS3 delivers a maximum airflow rate of 12.5 cubic meters per minute (m³/min) when operating at full capacity. This ensures efficient cabin temperature control in all driving conditions.
Q3 How does the dual-zone climate control system work in the Audi RS3?
How does the dual-zone climate control system work in the Audi RS3?
The dual-zone climate control system in the Audi RS3 allows the driver and front passenger to independently set their preferred temperature, ranging from 16°C to 29.5°C. The system uses separate sensors and actuators to maintain precise temperature control for each zone.
Q4 What is the power consumption of the HVAC system in the Audi RS3?
What is the power consumption of the HVAC system in the Audi RS3?
The HVAC system in the Audi RS3 has a maximum power consumption of approximately 1.2 kW when operating at full capacity. This includes the compressor, blower motor, and auxiliary heating or cooling components.
Q5 How often should the cabin air filter be replaced in the Audi RS3?
How often should the cabin air filter be replaced in the Audi RS3?
The cabin air filter in the Audi RS3 should be replaced every 15,000 to 20,000 miles or once a year, whichever comes first. A clogged filter can reduce HVAC efficiency and airflow.
Factory Service Resources
Access official service manuals, technical documents, and repair guides. These resources provide detailed procedures, specifications, and diagrams directly from the manufacturer.
Audi RS3 HVAC System Service Manual
Coming SoonOfficial service manual for the HVAC system, including detailed repair and maintenance procedures.
Refrigerant Handling and Safety Guidelines
Coming SoonComprehensive guide on handling R-1234yf refrigerant safely, including environmental and safety precautions.
Dual-Zone Climate Control Troubleshooting
Coming SoonStep-by-step troubleshooting guide for common issues with the dual-zone climate control system.
Cabin Air Filter Replacement Guide
Coming SoonDetailed instructions for replacing the cabin air filter in the Audi RS3, including tools and safety tips.
About the Author
Expert automotive knowledge and experience
Diagnostic
Specialized in advanced diagnostic techniques using modern scan tools and oscilloscopes.
Repair
Expert in both traditional mechanical repairs and modern vehicle systems.
Additional Expertise
Documentation
Created over 500 detailed repair guides and technical documents.
Training
Conducted technical training sessions and contributed to repair databases.
Certifications & Research
Certifications
- ASE Master Technician Certification
- Advanced Diagnostic Specialist
- Hybrid/Electric Vehicle Systems
- Performance Tuning Expert
Research & Community
Actively researches emerging technologies and contributes to automotive forums.
Legal Disclaimer
Important information about using this content
Always refer to your vehicle's service manual and take appropriate safety precautions when performing any maintenance or repairs.
General Information
Warranty & Liability
The content on this website is provided "as is" without any representations or warranties, express or implied. We make no representations or warranties regarding the accuracy, completeness, or availability of the information.
We shall not be liable for any direct, indirect, special, or consequential damages arising from the use of information on this website.
Technical Information
- All specifications, including torque values, fluid capacities, and maintenance procedures, should be verified against your vehicle's factory service manual.
- Vehicle specifications and procedures may vary by model year, trim level, and region.
- Always follow the manufacturer's recommended procedures and safety precautions.
- Working on vehicles can be dangerous. Always take proper safety precautions and use appropriate safety equipment.
- If you're unsure about any procedure, consult a qualified professional mechanic.