Audi Audi RS3 2011-2016 HVAC Specifications
Detailed technical specifications for the HVAC system in the 2011-2016 Audi RS3, including component details, performance metrics, and diagnostic procedures.
Overview Specifications
Comprehensive description of the HVAC specifications for the 2011-2016 Audi RS3, including key features, measurements, and technical details.
How to Use
Use the search function to locate specific HVAC specifications by entering keywords such as 'blower motor', 'refrigerant capacity', or 'temperature control'.
Navigate through the HVAC documentation sections using the table of contents or by scrolling through the document. Each section is clearly labeled for easy access.
Key Specifications
Refrigerant Capacity
525 ± 25 grams
Maximum Cooling Capacity
5.5 kW at 2000 rpm
Heater Core Capacity
2.5 liters
Blower Motor Power
200 W
Airflow Capacity
450 m³/h
Available Specifications
HVAC System Overview
This section provides an overview of the HVAC system, including its components, functionality, and integration with the vehicle's electronics.
HVAC System Overview
This section provides an overview of the HVAC system, including its components, functionality, and integration with the vehicle's electronics.
System Components
- Dual-zone automatic climate control system
- Electrically driven compressor for efficient cooling
- High-capacity blower motor with variable speed control
- Integrated air quality sensor for automatic recirculation
System Integration
- Fully integrated with the MMI (Multi Media Interface) system
- Supports automatic temperature adjustment based on GPS data
- Includes rear seat ventilation ducts for passenger comfort
- Compatible with Audi's pre-conditioning feature via the Audi Connect app
Note: The HVAC system is designed to work seamlessly with the vehicle's CAN bus network for real-time data exchange.
Refrigerant and Cooling Specifications
This section details the refrigerant type, capacity, and cooling performance specifications for the HVAC system.
Refrigerant and Cooling Specifications
This section details the refrigerant type, capacity, and cooling performance specifications for the HVAC system.
Refrigerant Type and Capacity
- Uses R134a refrigerant
- Total refrigerant capacity: 525 ± 25 grams
- Refrigerant oil type: PAG (Polyalkylene Glycol)
- Refrigerant oil capacity: 120 ± 10 ml
Cooling Performance
- Maximum cooling capacity: 5.5 kW at 2000 rpm
- Evaporator temperature range: 2°C to 10°C
- Condenser pressure: 12 to 18 bar under normal operating conditions
- Compressor displacement: 120 cc/rev
Note: Ensure refrigerant levels are within the specified range to maintain optimal cooling performance.
Heating and Ventilation Specifications
This section covers the heating and ventilation components, including the heater core, blower motor, and air distribution system.
Heating and Ventilation Specifications
This section covers the heating and ventilation components, including the heater core, blower motor, and air distribution system.
Heater Core Specifications
- Heater core material: Aluminum
- Heater core capacity: 2.5 liters
- Maximum heat output: 6.0 kW
- Coolant flow rate: 12 liters per minute
Blower Motor and Air Distribution
- Blower motor power rating: 200 W
- Airflow capacity: 450 m³/h at maximum speed
- Dual-zone air distribution with 12 adjustable vents
- Includes rear seat ventilation ducts with independent control
Note: The blower motor is designed for quiet operation, with noise levels below 45 dB at maximum speed.
Control System and Sensors
This section provides details on the HVAC control system, including sensors, actuators, and user interface components.
Control System and Sensors
This section provides details on the HVAC control system, including sensors, actuators, and user interface components.
Temperature Control Sensors
- Interior temperature sensor accuracy: ±0.5°C
- Exterior temperature sensor range: -40°C to 60°C
- Solar sensor for automatic sun load compensation
- Humidity sensor for automatic defogging
Actuators and User Interface
- Electronically controlled air mix actuators
- 8-inch MMI touchscreen for climate control settings
- Voice control compatibility for hands-free operation
- Includes physical rotary dials for quick adjustments
Note: The HVAC control system supports over-the-air updates via Audi Connect for enhanced functionality.
Search Specifications
Search by specification name, value, or description
Type to search through torque specifications. Results will appear below as you type.
Component Specifications
General Specifications
- System Type
- Automatic climate control with dual-zone temperature regulation
- Refrigerant Type
- R134a
- Refrigerant Capacity
- 525 ± 25 g
- Compressor Type
- Variable displacement swash plate compressor
- Compressor Part Number
- 8V0820803B
- Blower Motor Power
- 200 W
Temperature Control
- Temperature Range
- 16°C to 30°C
- Temperature Resolution
- 0.5°C
- Sensor Accuracy
- ±1°C
- Dual Zone Difference Limit
- 5°C
Airflow Specifications
- Blower Speeds
- 7 levels
- Max Airflow Rate
- 12.5 m³/min
- Air Distribution Modes
-
- Face
- Footwell
- Defrost
- Combined
- Recirculation Mode Flow Rate
- 8.2 m³/min
Heating System
- Heater Core Type
- Aluminum
- Heater Core Part Number
- 8V0819031A
- Max Heating Capacity
- 6.5 kW
- Coolant Flow Rate
- 12 L/min
- Coolant Temperature Range
- 80°C to 105°C
Cooling System
- Evaporator Type
- Plate-fin
- Evaporator Part Number
- 8V0820043C
- Cooling Capacity
- 4.2 kW
- Condenser Type
- Parallel flow
- Condenser Part Number
- 8V0820451D
Filters
- Cabin Air Filter Type
- Combination particulate and activated carbon
- Cabin Air Filter Part Number
- 8V0819439A
- Filter Replacement interval
- 15,000 miles or 12 months
- Filter Efficiency
- 95% for particles > 0.3 microns
Electrical Specifications
- System Voltage
- 12 V DC
- Compressor Clutch Power
- 60 W
- Blower Motor Current
- 16 A
- Control Module Part Number
- 8V0907044E
Operational Parameters
- Compressor Pressure Range
- 1.5 to 3.5 bar
- Evaporator Temperature Range
- 2°C to 10°C
- Condenser Temperature Range
- 50°C to 70°C
- System Shutdown Temperature
- 120°C
Diagnostic Specifications
- Diagnostic Tool
- VAS 6154 or equivalent
- Fault Codes
-
- B10A0
- B10A1
- B10A2
- Diagnostic interface
- OBD-II
- Self Diagnosis Capability
- Yes
Maintenance Specifications
- Refrigerant Recharge interval
- 24 months or as needed
- System Leak Test interval
- 24 months
- Lubricant Type
- PAG oil
- Lubricant Quantity
- 150 ± 10 ml
- System Flush interval
- 48 months or as needed
Service Information Service
Detailed service requirements and schedules for the HVAC system
- Inspect cabin air filter
- Check refrigerant level
- Inspect compressor belt tension
Replace cabin air filter if necessary
- Recharge refrigerant
- Perform system leak test
- Inspect evaporator and condenser for debris
Use only R134a refrigerant
- Flush HVAC system
- Replace lubricant
- Inspect all electrical connections
Follow Audi-recommended procedures for flushing
Frequently Asked Questions
Find answers to common questions about torque specifications
Q1 What is the refrigerant type and capacity for the 2011-2016 Audi RS3 HVAC system?
What is the refrigerant type and capacity for the 2011-2016 Audi RS3 HVAC system?
The 2011-2016 Audi RS3 HVAC system uses R134a refrigerant. The total system capacity is approximately 525 grams (18.5 ounces). Always ensure the refrigerant is handled and charged according to Audi specifications to avoid system damage.
Q2 What is the recommended interval for HVAC system maintenance?
What is the recommended interval for HVAC system maintenance?
Audi recommends inspecting the HVAC system every 20,000 miles or 24 months, whichever comes first. This includes checking refrigerant levels, cabin air filters, and system performance. Regular maintenance ensures optimal efficiency and prevents potential failures.
Q3 How do I reset the HVAC system after replacing the cabin air filter?
How do I reset the HVAC system after replacing the cabin air filter?
After replacing the cabin air filter, reset the HVAC system by accessing the service menu through the MMI (Multi Media Interface). Navigate to 'Service' > 'Cabin Filter' > 'Reset.' This ensures the system recognizes the new filter and maintains proper airflow.
Q4 What is the operating temperature range for the HVAC system?
What is the operating temperature range for the HVAC system?
The HVAC system in the 2011-2016 Audi RS3 operates effectively within an ambient temperature range of -22°F to 122°F (-30°C to 50°C). Extreme temperatures outside this range may affect performance and require additional system checks.
Q5 Can I use aftermarket refrigerant in the HVAC system?
Can I use aftermarket refrigerant in the HVAC system?
No, Audi strongly recommends using only genuine R134a refrigerant and approved lubricants. Aftermarket refrigerants may not meet Audi's specifications, potentially causing system damage, reduced performance, and voiding the warranty.
Factory Service Resources
Access official service manuals, technical documents, and repair guides. These resources provide detailed procedures, specifications, and diagrams directly from the manufacturer.
Audi HVAC System Service Manual
Coming SoonOfficial Audi service manual detailing HVAC system diagnostics, maintenance, and repair procedures for the 2011-2016 RS3.
Cabin Air Filter Replacement Guide
Coming SoonStep-by-step guide for replacing the cabin air filter in the 2011-2016 Audi RS3, including resetting the HVAC system.
Refrigerant Handling and Safety Guidelines
Coming SoonComprehensive guide on handling R134a refrigerant safely, including proper charging procedures and safety precautions.
HVAC System Troubleshooting
Coming SoonDiagnostic guide for common HVAC system issues in the 2011-2016 Audi RS3, including error codes and solutions.
About the Author
Expert automotive knowledge and experience
Diagnostic
Specialized in advanced diagnostic techniques using modern scan tools and oscilloscopes.
Repair
Expert in both traditional mechanical repairs and modern vehicle systems.
Additional Expertise
Documentation
Created over 500 detailed repair guides and technical documents.
Training
Conducted technical training sessions and contributed to repair databases.
Certifications & Research
Certifications
- ASE Master Technician Certification
- Advanced Diagnostic Specialist
- Hybrid/Electric Vehicle Systems
- Performance Tuning Expert
Research & Community
Actively researches emerging technologies and contributes to automotive forums.
Legal Disclaimer
Important information about using this content
Always refer to your vehicle's service manual and take appropriate safety precautions when performing any maintenance or repairs.
General Information
Warranty & Liability
The content on this website is provided "as is" without any representations or warranties, express or implied. We make no representations or warranties regarding the accuracy, completeness, or availability of the information.
We shall not be liable for any direct, indirect, special, or consequential damages arising from the use of information on this website.
Technical Information
- All specifications, including torque values, fluid capacities, and maintenance procedures, should be verified against your vehicle's factory service manual.
- Vehicle specifications and procedures may vary by model year, trim level, and region.
- Always follow the manufacturer's recommended procedures and safety precautions.
- Working on vehicles can be dangerous. Always take proper safety precautions and use appropriate safety equipment.
- If you're unsure about any procedure, consult a qualified professional mechanic.